Anritsu MS9740A 光學頻譜分析儀|Optical Spectrum Analyzer (OSA)|MS9740A

Anritsu MS9740A 為安立(Anritsu)經典 Optical Spectrum Analyzer(OSA 光學頻譜分析儀),可用…

品牌:安立知 (Anritsu) 型號:MS9740A 料號:PD1529656402951
【弘燁科技】Anritsu MS9740A 光學頻譜分析儀|Optical Spectrum Analyzer (OSA)|MS9740A
品牌
安立知 (Anritsu)
型號
MS9740A
類別
規格資料
已整理
文件下載
可下載

產品介紹

Anritsu MS9740A 為安立(Anritsu)經典 Optical Spectrum Analyzer(OSA 光學頻譜分析儀),可用於量測光源光譜、雷射波長、通道功率分佈與光訊號特性,廣泛應用於光通訊與光電研發 / 產線測試。

MS9740A 常見於 WDM / DWDM 系統驗證、光收發器模組測試、雷射 / EDFA 評估、濾波器與光學元件量測等情境,可協助工程師快速進行光譜分析、波長穩定度與通道功率驗證,是光通訊實驗室與製造測試常用的 OSA 設備之一。

常見於光通訊研發、QA 與產線測試,適用於:雷射光源量測(Laser Wavelength / Stability) WDM / DWDM 光通訊訊號分析(Channel Power / Wavelength) 光譜分析與光功率量測(Optical Spectrum / Power Distribution) 光收發器模組測試(SFP / QSFP 等) EDFA / 光放大器增益特性評估 光學濾波器、光柵、耦合器等元件量測

規格

原廠完整規格表 / Full Specifications

以下整理原廠完整規格表,供型號確認、規格比對與詢價確認使用。

SpecificationsDetails

MS9740A
MS9740A-009
Applicable optical fiber

10 μm/125 μm SM fiber (ITU-T G.652), 50 μm/125 μm GI fiber 10 μm/125 μm SM fiber (ITU-T G.652), 50 μm/125 μm GI fiber, 62.5 μm/125 μm GI fiber

Optical connector

User replaceable: FC, SC, ST, DIN

Wavelength measurement range

600 nm to 1750 nm
Wavelength accuracy

±20 pm (1520 nm to 1620 nm, Resolution: 0.03 to 0.2 nm)*1, *2 ±100 pm (1520 nm to 1620 nm, Resolution: 0.5, 1.0 nm)*1, *2 ±50 pm (1530 nm to 1570 nm, Resolution: 0.07 to 0.2 nm)*3, *4

±100 pm (1530 nm to 1570 nm, Resolution: 0.5, 1.0 nm)*3, *4

Setting resolution

0.03, 0.05, 0.07, 0.1, 0.2, 0.5, 1.0 nm

(RBW: 3 dB optical filter: transmission bandwidth)

0.07, 0.1, 0.2, 0.5, 1.0 nm

(RBW: 3 dB optical filter: transmission bandwidth)
Maximum input power
+23 dBm (Optical ATT: On)
Dynamic range
High dynamic range60 dB (0.4 nm from peak wavelength)*1
Normal dynamic range58 dB (0.4 nm from peak wavelength)*1
[Resolution0.05 nm, 1550 nm, Optical ATT: Off, 20° to 30°C]
High dynamic range60 dB (0.5 nm from peak wavelength)*3
Normal dynamic range58 dB (0.5 nm from peak wavelength)*3
[Resolution0.07 nm, 1550 nm, using SM fiber, Optical ATT: Off, 20° to 30°C]
Sweep
Sweep width0.2 nm to 1200 nm, 0 nm
Sweep speed≤0.2 sec. (Span 5 nm)
[Resolution0.1 nm, VBW=10 kHz, Normal dynamic range, center 1550 nm, sweep start to stop, no optical input, sampling point: ≤501]
Dimensions and Mass

426 (W) × 177 (H) × 350 (D) mm (excluding projections) ≤15.0 kg (without option) *1: Using SM fiber (ITU-T G.652), after 2 hours of warm-up (the Repeat sweeping performed at Span 100 nm or more and VBW 10 kHz or more during the warm-up operation), after Auto Align, at stable room temperature.

*2: Built-in option 002, after Wl cal (ref) wavelength calibration execution, at stable room temperature. *3:

Warm-up the instrument for at least 2 hours before measurement by performing repeated sweeping at span ≥100 nm, VBW = 10 kHz. Perform waveform calibration after auto-optical alignment (WI Cal) and keep the instrument at the same temperature unless stated otherwise. Use either SM fiber (ITU-T G.652) or GI fiber (50 μm/125 μm) with a return loss of >40 dB, or GI fiber (62.5 μm/125 μm) with a return loss of >38 dB. *4: Built-in MS9740A-002, after Wl Cal (Ref), with SM fiber.

原廠英文說明
  • Measurement of passive optical devices in <0.2s(5nm) reduces total analysis time
  • Dedicated applications for evaluating active optical devices
  • Excellent cost performance
  • Dynamic range performance ≥60 dB (0.4 nm from peak wavelength)
  • 30 pm minimum resolution bandwidth
  • Supports SM and MM fibers
  • Lightweight, 50% less power consumption