Anritsu MS9740A Optical Spectrum Analyzer
Anritsu MS9740A Optical Spectrum Analyzer

Wavelength measurement range: 600 nm to 1750 nm

產品介紹
  • 儀器介紹
  • 儀器規格
  • 檔案下載
  • Measurement of passive optical devices in <0.2s(5nm) reduces total analysis time
  • Dedicated applications for evaluating active optical devices
  • Excellent cost performance
  • Dynamic range performance ≥60 dB (0.4 nm from peak wavelength)
  • 30 pm minimum resolution bandwidth
  • Supports SM and MM fibers
  • Lightweight, 50% less power consumption

 

SpecificationsDetails
  MS9740A MS9740A-009
Applicable optical fiber 10 μm/125 μm SM fiber (ITU-T G.652), 50 μm/125 μm GI fiber 10 μm/125 μm SM fiber (ITU-T G.652), 50 μm/125 μm GI fiber, 62.5 μm/125 μm GI fiber
Optical connector User replaceable: FC, SC, ST, DIN
Wavelength measurement range 600 nm to 1750 nm
Wavelength accuracy ±20 pm (1520 nm to 1620 nm, Resolution: 0.03 to 0.2 nm)*1, *2 
±100 pm (1520 nm to 1620 nm, Resolution: 0.5, 1.0 nm)*1, *2
±50 pm (1530 nm to 1570 nm, Resolution: 0.07 to 0.2 nm)*3, *4 
±100 pm (1530 nm to 1570 nm, Resolution: 0.5, 1.0 nm)*3, *4
Setting resolution 0.03, 0.05, 0.07, 0.1, 0.2, 0.5, 1.0 nm
(RBW: 3 dB optical filter: transmission bandwidth)
0.07, 0.1, 0.2, 0.5, 1.0 nm
(RBW: 3 dB optical filter: transmission bandwidth)
Maximum input power +23 dBm (Optical ATT: On)
Dynamic range High dynamic range: 60 dB (0.4 nm from peak wavelength)*1 
Normal dynamic range: 58 dB (0.4 nm from peak wavelength)*1 
[Resolution: 0.05 nm, 1550 nm, Optical ATT: Off, 20° to 30°C]
High dynamic range: 60 dB (0.5 nm from peak wavelength)*3 
Normal dynamic range: 58 dB (0.5 nm from peak wavelength)*3 
[Resolution: 0.07 nm, 1550 nm, using SM fiber, Optical ATT: Off, 20° to 30°C]
Sweep Sweep width: 0.2 nm to 1200 nm, 0 nm 
Sweep speed: ≤0.2 sec. (Span 5 nm) 
[Resolution: 0.1 nm, VBW=10 kHz, Normal dynamic range, center 1550 nm, sweep start to stop, no optical input, sampling point: ≤501]
Dimensions and Mass 426 (W) × 177 (H) × 350 (D) mm (excluding projections) ≤15.0 kg (without option)

 

*1:  Using SM fiber (ITU-T G.652), after 2 hours of warm-up (the Repeat sweeping performed at Span 100 nm or more and VBW 10 kHz or more during the warm-up operation), after Auto Align, at stable room temperature.
*2:  Built-in option 002, after Wl cal (ref) wavelength calibration execution, at stable room temperature.
*3:  Warm-up the instrument for at least 2 hours before measurement by performing repeated sweeping at span ≥100 nm, VBW = 10 kHz. Perform waveform calibration after auto-optical alignment (WI Cal) and keep the instrument at the same temperature unless stated otherwise. Use either SM fiber (ITU-T G.652) or GI fiber (50 μm/125 μm) with a return loss of >40 dB, or GI fiber (62.5 μm/125 μm) with a return loss of >38 dB.
*4:  Built-in MS9740A-002, after Wl Cal (Ref), with SM fiber.